7.3 Power Problems
Table 7–5 Troubleshooting Power Problems
If the power indicator is: Check:
Off
Front-panel power switch
Power at the wall receptacle
AC cord
Power cable connectors
Side cover (pedestal) or top cover (rack).
Interlocking sensor switch shuts off power if the
cover is removed.
Unplug the power cords for 15 seconds, then
reconnect.
On for a few seconds and Power supply fan. Listen to hear if the power
then goes Off supply fan is spinning at power-up. A failure of the
fan causes the system to shut down after a few
seconds.
NOTE: The power supply shuts off within one
second if its internal fan fails.
On, but the monitor
Monitor power indicator is On.
screen is blank
Video cable is properly connected.
SRM console environment variable setting.
NOTE: A black raster is displayed if the
console environment variable is set to serial
mode rather than graphics mode.