Operating instructions
set init
The set init command sets the modem initialization string.
The initialization string is limited to 31 characters and can be modified, depend-
ing on the type of modem used.
RMC> set init
Init String: AT&F0E0V0X0S0=2
RMC>
Because the modem commands disallow mixed cases, the RMC automatically
converts all alphabetic characters entered in the init string to uppercase.
The RMC automatically configures the modem’s flow control according to the
setting of the SRM com1_flow environment variable. The RMC also enables
the modem carrier detect feature to monitor the modem connectivity.
set logout
The set logout command sets the amount of time before the RMC terminates
an inactive modem connection. The default is 20 minutes.
The settings are in tens of minutes, 0–9. The zero (0) setting disables logout.
With logout disabled, the RMC never disconnects the idle modem session.
The following example sets the logout timer to 30 minutes.
RMC> set logout
Logout Time (0-9 tens of minutes): 3
Remote Management 6-39