Technical data

Example 4–3 Checking SCSI Devices
>>>SHOW SCSI
SCSI Adapter A, SCSI ID 6
-DKA300 (DEC RZ24L)
-DKA700 (DEC RRD42)
If you do not see the names and and IDs of the devices, see the VAX 4000
Model 100A Troubleshooting and Diagnostics Information manual.
4.5 Connecting Peripherals
The following subsections contain information on the following tasks:
Connecting peripherals to a DEC423 MMJ port
Connecting a peripheral to the asynchronous modem control port (port 2)
Connecting peripherals to an optional asynchronous port
Connecting peripherals to an optional synchronous port
4.5.1 Connecting Peripherals to a DEC423 MMJ Port
Note
When the system is shipped, MMJ ports 0 and 1 are covered with an
arrow label identifying port 3 as the console port. When port 3 has
been identified, the OPA0 arrow label may be removed.
To connect peripherals that use DEC423 cables (BC16E) to MMJ ports 0, 1, or
3, follow these steps:
1. Set the on/off switch on the peripheral to the off (O) position.
2. Connect one end of the DEC423 cable to either MMJ port 0, 1, or 3 (see
Figure 4–3).
Note
In some countries, the peripheral cable has an earth drain wire.
Connect this earth drain wire to the grounding pillar above MMJ port
1 using the screw provided with the cable.
4–12 Hardware Options