PARAMS>SHOW ALLCLASS
Parameter Current Default Type Radix
--------- ---------------- ---------------- -------- -----
ALLCLASS 0 0 Byte Dec B
PARAMS>SET ALLCLASS 2
PARAMS>SHOW ALLCLASS
Parameter Current Default Type Radix
--------- ---------------- ---------------- -------- -----
ALLCLASS 2 0 Byte Dec B
C.3.3 Setting the Unit Number
After entering the DUP driver utility for a specified device, you can examine
and set the unit number for the device as follows.
1. At the
PARAMS>
prompt, enter
SHOW UNITNUM
to check the unit number of
the ISE to which you are currently connected.
2. Enter
SET UNITNUM 10
(or enter the unit number you desire).
3. Enter
SET FORCEUNI 0
to override the default unit number value supplied
by the bus node ID plug.
4. Enter
SHOW UNITNUM
to verify the new unit number.
5. Enter
SHOW FORCEUNI
to verify that the current value for the
FORCEUNI
parameter is 0.
This shows the steps for changing the unit number of a specified device
from 0 to 10.
PARAMS>SHOW UNITNUM
Parameter Current Default Type Radix
--------- ---------------- ---------------- -------- -----
UNITNUM 0 0 Word Dec U
PARAMS>SET UNITNUM 10
PARAMS>SET FORCEUNI 0
PARAMS>SHOW UNITNUM
Parameter Current Default Type Radix
--------- ---------------- ---------------- -------- -----
UNITNUM 10 0 Word Dec U
PARAMS>SHOW FORCEUNI
Parameter Current Default Type Radix
--------- ---------------- ---------------- -------- -----
FORCEUNI 0 1 Boolean 0/1 U
6. Label the device with its unit number, using the unit number labels
shipped with your system.