Service manual

Troubleshooting 3-7
If Power Problem Occurs at Power-Up
If the system has a power problem on a cold start, the PCM LEDs are not valid until
after DCOK_SENSE has been asserted. The cause is one of the following:
Broken system fan
Broken CPU fan
Power supplied to the system is out of tolerance (a power supply could be
broken and the system could still power up)
PCM failure
Interlock failure
Wire problems
Temperature problem (unlikely)
Recommended Order for Troubleshooting Failure at Power-Up
1. Check to see if any CPU fan or system fan is not spinning. Fans can fail by not
spinning and/or not putting out the tachometer output necessary as input to the
PCM comparator that checks the fans. (See steps 4 and 5.) Replace broken fan.
2. Replace the PCM.
3. Sequentially remove CPUs and try to power up after you remove a CPU. If the
system powers up, the last CPU you removed had a fan failure.
4. Check the output of the power supplies. See Section 4.1 for locations of +5 and
+3.43 volt output pins. If the output is above or below the threshold, replace the
faulty power supply.
5. Check the output of each system fan with a voltmeter. Probe the middle of three
outputs of the fans with the positive lead of the meter and ground the other
probe. The meter should read 2.5 volts to 3 volts. If a fan’s output is out of this
range, replace the fan.
NOTE: You will have to disable the interlocks to check the voltages in step 5.
You will have only 10 seconds to measure them. There is a 10-second delay
before the PCM turns off the power.
The PCM must sense a change in Vaux (auxiliary voltage) to start the power
supplies. Pressing the On button has no effect if the machine halted because of
a failure in the power system. The power supplies must be unplugged and
plugged back in for the On button to work.