Service manual

Power-Up 2-15
2.6 XSROM Errors Reported
The XSROM reports B-cache test errors and memory test errors. It also
reports a warning if memory is illegally configured.
Example 2-2 XSROM Errors Reported at Power-Up
B-cache Error (CPU Error)
TEST ERR on cpu0 #CPU running the test
FRU cpu0
err# 2
tst# 11
exp: 5555555555555555 #Expected data
rcv: aaaaaaaaaaaaaaaa #Received data
adr: ffff8 #B-cache location error
#occurred
Memory Error (Memory Module Indicated)
20..21..
TEST ERR on cpu0 #CPU running test
FRU: MEM1L #Low member of memory pair 1
err# c
tst# 21
22..23..24..Memory testing complete on cpu0
Memory Configuration Error (Operator Error)
ERR! mem_pair0 misconfigured
ERR! mem_pair1 card size mismatch
ERR! mem_pair1 card type mismatch
ERR! mem_pair1 EMPTY
FEPROM Failures (PCI Motherboard Error)
Sctr 1 -PAL headr PTTRN fail
Sctr 1 -PAL headr CHKSM fail
Sctr 1 -PAL code CHKSM fail
Sctr 3 -CONSLE headr PTTRN fail
Sctr 3 -CONSLE headr CHKSM fail
Sctr 3 -CONSLE code CHKSM fail