Service manual

Power-Up 2-3
Table 2–1 Control Panel Display
Field Content Display Meaning
CPU number P0–P3 CPU reporting status
Status TEST Tests are executing
FAIL Failure has been detected
MCHK Machine check has occurred
INTR Error interrupt has occurred
Test number
Suspected device CPU0–3 CPU module number
1
MEM0–3 and
L, H, or *
Memory pair number and low
module, high module, or either
2
IOD0 Bridge to PCI bus 0
3
IOD1 Bridge to PCI bus 1
3
IOD2 Bridge to PCI bus 2
4
IOD3 Bridge to PCI bus 3
4
FROM0 Flash ROM
5
COMBO COM controller
5
PCEB PCI-to-EISA bridge
5
ESC EISA system controller
5
NVRAM Nonvolatile RAM
5
TOY Real-time clock
5
I8242 Keyboard and mouse controller
5
The potentiometer, accessible through the access hole just above the Reset button
controls the intensity of the LCD. Use a small Phillips head screwdriver to adjust.
1
CPU module
2
Memory module
3
Bridge module (B3040-AA)
4
Bridge module (B3040-AB)
5
EISA/PCI motherboard