Service manual

C-14 AlphaServer 4000/4100 Service Manual
C.1.3.15 status
The status command displays the current state of the server’s sensors, as well as the
current escape sequence and alarm information.
RCM>status
Firmware Rev: V1.0
Escape Sequence: ^]^]RCM
Remote Access: ENABLE/DISABLE
Alerts: ENABLE/DISABLE
Alert Pending: YES/NO (C)
Temp (C): 26.0
RCM Power Control: ON/OFF
External Power: ON
Server Power: OFF
RCM>
The status fields are explained in Table C-2.
Table C-2 RCM Status Command Fields
Item Description
Firmware Rev: Revision of RCM firmware.
Escape Sequence: Current escape sequence to enter RCM firmware
console.
Remote Access: Modem remote access state. (ENABLE/DISABLE)
Alerts: Alert dial-out state. (ENABLE/DISABLE)
Alert Pending: Alert condition triggered. (YES/NO)
Temp (C): Current system temperature in degrees Celsius.
RCM Power Control: Current state of RCM system power control.
(ON/OFF)
External Power: Current state of power from external power supply
to server control module. (ON/OFF)
Server Power: Current state of system power. (ON/OFF)