Operating the System Remotely C-11
C.1.3.10 poweron
The poweron command requests the RCM module to power on the system. For the
system power to come on, the following conditions must be met:
AC power must be present at the power supply inputs.
The DC On/Off button must be in the “on” position.
All system interlocks must be set correctly.
The RCM firmware console exits command mode and reconnects the user’s terminal
to the system console port.
RCM>poweron
Focus returned to COM port
NOTE: If the system is powered off with the DC On/Off button, the system will not
power up. The RCM will not override the “off” state of the DC On/Off button. If the
system is already powered on, the poweron command has no effect.
C.1.3.11 quit
The quit command exits the user from command mode and reconnects the user’s
terminal to the system console port. The following message is displayed:
Focus returned to COM port
The next display depends on what the system was doing when the RCM was
invoked. For example, if the RCM was invoked from the SRM console prompt, the
console prompt will be displayed when you enter a carriage return. Or, if the RCM
was invoked from the operating system prompt, the operating system prompt will be
displayed when you enter a carriage return.