Service manual

C-8 AlphaServer 4000/4100 Service Manual
C.1.3.1 alert_clr
The alert_clr command clears an alert condition within the RCM. The alert enable
condition remains active, and the RCM will again enter the alert condition when it
detects a system power failure.
RCM>alert_clr
C.1.3.2 alert_dis
The alert_dis command disables RCM dial-out capability. It also clears any
outstanding alerts. The alert disable state is nonvolatile. Dial-out capability remains
disabled until the alert_enable command is issued.
RCM>alert_dis
C.1.3.3 alert_ena
The alert_ena command enables the RCM to automatically dial out when it detects
a power failure within the system. The RCM repeats the dial-out alert at 30-minute
intervals until the alert is cleared. The alert enable state is nonvolatile. Dial-out
capability remains enabled until the alert_disable command is issued.
RCM>alert_ena
In order for the alert_enable command to work, two conditions must be met:
A modem dial-out string must be entered with the system console.
Remote access to the RCM modem port must be enabled with the enable
command.
If the alert_enable command is entered when remote access is disabled, the
following message is returned:
*** error ***