Service manual

Running Utilities A-17
The update command updates the device specified or all devices.
For each device, you are asked to confirm that you want to update the
firmware. The default is no. Once the update begins, do not abort the
operation. Doing so will corrupt the firmware on the module.
The lfu command restarts the utility so that console firmware can be updated.
(Another method is shown in Example A-5, where the user specifies the file
AS4X00FW and is prompted to insert the second diskette.)
The default update file, AS4X00CP, is selected. The console firmware can now
be updated, using the same procedure as for the I/O firmware.
The exit command returns you to the console from which you entered LFU
(either SRM or AlphaBIOS).
Example A-5 Selecting AS4X00FW to Update Firmware from the
Internal Floppy Disk
P00>>> lfu
***** Loadable Firmware Update Utility *****
Select firmware load device (cda0, dva0, ewa0), or
Press <return> to bypass loading and proceed to LFU: dva0
Please enter the name of the firmware files list, or
Press <return> to use the default filename [AS4X00IO,(AS4X00CP)]: as4x00fw
Copying AS4X00FW from DVA0 .
Copying RHREADME from DVA0 .
Copying RHSRMROM from DVA0 ..........................
Copying RHARCROM from DVA0 ...............
Copying CIPCA214 from DVA0
Please insert next floppy containing the firmware,
Press <return> when ready. Or type DONE to abort.
Copying CIPCA214 from DVA0 .
Copying DFPAA246 from DVA0 ...
Copying KZPSAA10 from DVA0 ...
.
.
.