Service manual
A-14 AlphaServer 4000/4100 Service Manual
A.5.3 Updating Firmware from the Internal Floppy Disk —
Performing the Update
Insert an update diskette (see Section A.5.2) into the internal floppy drive. Start
LFU and select dva0 as the load device.
Example A-4 Updating Firmware from the Internal Floppy Disk
***** Loadable Firmware Update Utility *****
Select firmware load device (cda0, dva0, ewa0), or
Press <return> to bypass loading and proceed to LFU: dva0
➊
Please enter the name of the options firmware files list, or
Press <return> to use the default filename [AS4X00IO,(AS4X00CP)]:
AS4X00IO
➋
Copying AS4X00IO from DVA0 .
Copying RHREADME from DVA0 .
Copying CIPCA214 from DVA0 .
Copying DFPAA252 from DVA0 ...
Copying KZPSAA11 from DVA0 ...
.
. (The function table displays, followed by the UPD> prompt, as
. shown in Example A-2.)
UPD> list
➌
Device Current Revision Filename Update Revision
AlphaBIOS V5.12-3 arcrom Missing file
pfi0 2.46 dfpaa_fw 2.52
srmflash T3.2-21 srmrom Missing file
cipca_fw A214
kzpsa_fw A11
Continued on next page