Service manual

Running Utilities A-5
A.4 Running RAID Standalone Configuration Utility
The RAID Standalone Configuration Utility is used to set up RAID disk drives
and logical units. The Standalone Utility is run from the AlphaBIOS Utility
menu.
The AlphaServer 4100 system supports the KZPSC-xx PCI RAID controller
(SWXCR). The KZPSC-xx kit includes the controller, RAID Array 230 Subsystems
software, and documentation.
1. Start AlphaBIOS Setup. If the system is in the SRM console, issue the
command alphabios. (If the system has a graphics monitor, you can set the
SRM console environment variable to graphics.)
2. At the Utilities screen, select Run Maintenance Program. Press Enter.
3. In the Run Maintenance Program dialog box, type swxcrmgr in the Program
Name: field.
4. Press Enter to execute the program. The Main menu displays the following
options:
[01.View/Update Configuration]
02.Automatic Configuration
03.New Configuration
04.Initialize Logical Drive
05.Parity Check
06.Rebuild
07.Tools
08.Select SWXCR
09.Controller Setup
10.Diagnostics
Refer to the RAID Array Subsystems documentation for information on using the
Standalone Configuration Utility to set up RAID drives.