Service manual
7-10 AlphaServer 4000/4100 Service Manual
7.4 4000 Power System FRUs
Figure 7-3 Location of 4000 Power System FRUs
PS0
PS1
PS2
Fan 0
Fan 1
Fan 2
B3040
B3040
P
C
M
B3050
B3051
54-23805-01
(4000 Motherb.)
P
o
w
e
r
S
t
r
i
p
AC
Input
Box
OCP
OCP
FLPY
CD
Pedestal
Tr ay
Interlock
SCSI
Cabinet
To Pedestal
Power
Source
To Cabinet
Power
Source
PKW-0401C-96
13
14
1
10
11
12
4
5
6
7
9
8
2
3
2a
Note: Only power cables are shown. Systems have
only one OCP located in either the cabinet tray or the
pedestal tray. Thicker lines indicate cables present
in both cabinets. Thinner lines are cables in the
pedestal only. Callout is intentionally missing.
Fan
Tr ay
Tray
Part Number Description
1 30-45353-01
30-45353-02
AC input box; only in cabinet systems: The 01 variant is for N.
Amer./Japan and has a NEMA L6-30P power cord; the 02 variant is
for Europe and AP and has an IEC 309 power cord.
2 12-23501-01
12-45334-02
AC power strip: The 12-23501-01 is used on pedestals in N.
Amer./Japan only and has six NEMA outlets and a 15 ft. cord to the
wall outlet; the 12-45334-02 is used on pedestals in Eur./AP and on
cabinet systems worldwide and has six IEC320 outlets. In pedestal
systems, cords match country-specific wall outlets.