Service manual
5-32 AlphaServer 4000/4100 Service Manual
Esample 5-5 MCHK 660 IOD-Detected Failure (PCI Error)
Logging OS 2. DIGITAL UNIX
System Architecture 2. Alpha
Event sequence number 2.
Timestamp of occurrence 27-AUG-1996 08:15:41
Host name mason3
System type register x00000016 AlphaStation 4x00
Number of CPUs (mpnum) x00000003
CPU logging event (mperr) x00000000
➊
Event validity 1. O/S claims event is valid
Event severity 1. Severe Priority
Entry type 100. CPU Machine Check Errors
CPU Minor class 2. 660 Entry
Software Flags x0000002300000000
IOD 0 Register Subpkt Pres
IOD 1 Register Subpkt Pres
PCI 1 Bus Snapshot Present
Active CPUs x00000007
Hardware Rev x00000000
System Serial Number NI62503MWE
Module Serial Number
Module Type x0000
System Revision x00000000
* MCHK 660 Regs *
Flags: x00000000
PCI Mask x0002
Machine Check Reason x0202 IOD-Detected Hard Error -OR-
DTag Parity Error (If Cached CPU)
PAL SHADOW REG 0 x0000000000000000
PAL SHADOW REG 1 x0000000000000000
PAL SHADOW REG 2 x0000000000000000
PAL SHADOW REG 3 x0000000000000000
PAL SHADOW REG 4 x0000000000000000
PAL SHADOW REG 5 x0000000000000000
PAL SHADOW REG 6 x0000000000000000
PAL SHADOW REG 7 x0000000000000000
PALTEMP0 xFFFFFFFFB589C000
PALTEMP1 x0000000000000000
PALTEMP2 xFFFFFC000043CDA0
PALTEMP3 x0000000000007C00
PALTEMP4 x0000000000000003
PALTEMP5 x0000000000000000
PALTEMP6 x000000000001C6AF
PALTEMP7 xFFFFFC000043C820
PALTEMP8 x1F1E171515020100
PALTEMP9 xFFFFFC000043CB10
PALTEMP10 xFFFFFC0000433E0C
PALTEMP11 xFFFFFC000043C970
PALTEMP12 xFFFFFC000043CD10
PALTEMP13 x0000000000026E80
PALTEMP14 x0000000000000000
PALTEMP15 x00000000000E0000
PALTEMP16 x0000020306600001
PALTEMP17 x0000000000000000
PALTEMP18 x0000000000000000
PALTEMP19 xFFFFFFFFB589F958
PALTEMP20 x00000000009D2000