User's Manual
16  Appendix A—Technical specifications 
Environmental and power specifications  
Environmental ranges 
Recommended operating 
temperature 
15 to 32º C (59 to 90º F) 
Maximum operating 
temperature 
40º C (104º F) 
Storage temperature  -40 to 60º C (-40 to 140º F) 
Recommended operating 
humidity 
15 to 80 percent, non-condensing  
Non-operating humidity  15 to 90 percent, non-condensing 
Operating altitude  Up to 2400 m (8000 ft) 
Power specifications
18
  Input requirements: 100 to 240 VAC, 50/60 Hz 
Power consumption
19
Maximum  50 watts 
Active  15 watts, Best mode 
20 watts, Normal mode 
26 watts, Fast Draft mode 
Off  0.75 watts  
Sleep  4.1 watts  
Ready  6 watts  
Scanning  13 watts 
  ENERGY STAR® qualified models, see www.hp.com/energystar 
Power certifications   
EMC  CISPR 22: 2005/EN 55022: 2006 Class B, EN 55024: 1998+A1: 2001+A2: 2003, EN 61000-3-2: 
2006, EN 61000-3-3: 1995+A1: 2001; FCC CFR 47, Part 15 Class B/ICES-003, Issue 4 Class B 
Safety  IEC 60950-1: 2001/EN 60950-1: 2001+A11: 2004; EN 60825-1 1994+A1: 2002+A2: 2001; UL 
60950-1: 2003 CAN/CSA-22.2 No. 60950-1-03; AS/NZS 60950: 2000, GB4943: 2001; NOM-019-
SCFI-1998 