User's Manual
Chapter 4 47
Protocol Specific Configuration
Poll/Select/Option Configuration Values
When choosing values for timers, it is preferable to choose the resolution
that has the longest interval but is still suitable for your application.
Poll Word
Val Res Minimum
Timeout
Maximum
Timeout
1 10msec 10msec 20msec
2 10msec 30msec 40msec
31 10 msec 610 msec 620 msec
1 100 msec 100 msec 200 msec
4 100 msec 300 msec 400 msec
31 100 msec 6100 msec 6200 msec
1 1 sec 1 sec 2 sec
8 1 sec 15 sec 16 sec
31 1sec 61sec 62sec
1 10 sec 10 sec 20 sec
16 10 sec 310 sec 320 sec
31 10 sec 610 sec 620 sec
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
U/N UI N201 (1-16383 bytes) See note below
U/N Configure port as user or network side:
0 = Port to act as network side
1 = Port to act as user side
UI Configure terminal as a UI (Unnumbered Information) terminal:
0 = Terminal is not a UI terminal
1 = Terminal is a UI terminal
N201 Maximum number of bytes in the largest acceptable I field. Values
from 1 to 16,383.