Troubleshooting guide

Citrix MetaFrame
Troubleshooting Guide 335795-006 6–3
Window size must be between 300
and 2048.
The Custom Width and Height fields
on the Window page of the Properties
dialog box can take values between 300
and 2048 only.
Data has been changed. Are you
sure you want to quit?
You are quitting from the ICA client with-
out saving changes to the current con-
nection entry.
Cannot write file:
file
. This message indicates a problem with
saving or creating a connection data-
base (for example, no disk space).
Invalid Error: Cannot start Wfica
with this connection.
The connection entry is invalid.
Cannot find selected connection,
or cannot find specified connec-
tion.
The configuration file is corrupt. Create
a new configuration file.
Error in configuration file:
file
Miss-
ing section:
section
The configuration file is corrupt. Create
a new configuration file.
Inconsistency in configuration file:
file
Missing section:
section
The configuration file is corrupt. Create
a new configuration file.
This description is already in use.
The Description must be unique.
The Description field on the Network
page of the Properties dialog box must
be unique.
Cannot get address for server
server
.
The server name cannot be resolved.
Unable to perform update: client is
not on local file system.
The client cannot update an installation
on a non-local (for example, NFS-
mounted) file system.
Unable to perform update: Not run-
ning $ICAROOT/wfica.
The client cannot update an installation
other than its own.
Citrix Error Messages
(Continued)
Error Message Meaning