Datasheet

System Unit
System UnitSystem Unit
System Unit
Dimensions
DimensionsDimensions
Dimensions
(HxWxD)
14.49 x 6.50 x 15.31 in
368x 165 x 389mm
Weight
WeightWeight
Weight
15.28 lbs ~15.83 lbs
6.932 kg ~7.18 kg
Packaging Dimensions
Packaging DimensionsPackaging Dimensions
Packaging Dimensions
(LxWxH)
19.52 x 9.45 x 20.39 in
496x 240 x 518 mm
Shipping Weight
Shipping WeightShipping Weight
Shipping Weight
21.94 lbs ~22.49 kg
9.952 kg ~10.2 kg
Temperature
TemperatureTemperature
Temperature
Operating
32° to 104° F (0to 40° C)
Non-operating
-22° to 149° F (-30° to 65° C)
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
Operating
10% to 90% (non-condensing at ambient)
Non-operating
5% to 95% (non-condensing at ambient)
Shock
ShockShock
Shock
Operating
40 G, half-sine
Non-operating
35G, T-Shock, 165 cm/sec half sine, 2-3 ms
Maximum Altitude
Maximum AltitudeMaximum Altitude
Maximum Altitude
(unpressurized)
Operating
10,000 ft (3048 m)
Non-operating
30,000 ft (9144 m)
Environmental
EnvironmentalEnvironmental
Environmental
TAA Compliant
Yes
For accessibility information on HP products, please visit:
http://www.hp.com/accessibility
.
Unit Environment and
Unit Environment andUnit Environment and
Unit Environment and
Operating Conditions
Operating ConditionsOperating Conditions
Operating Conditions
General Unit Operating Guidelines
General Unit Operating GuidelinesGeneral Unit Operating Guidelines
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and
cold, to ensure that unit is operated within the specified operating range.
Leave a 4 in (10.2 cm) clearance on all vented sides of the computer to permit the required
airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are
subject to each other's re-circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer.
Lint, dust and other foreign matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must
be provided on the enclosure, and the same operating guidelines listed above will still apply.
QuickSpecs
HP Pro 3400 Microtower Business PC
HP Pro 3400 Microtower Business PCHP Pro 3400 Microtower Business PC
HP Pro 3400 Microtower Business PC
Technical Specifications
DA - 14119 North America — Version 5 — February 6, 2012
Page 9