- Hewlett-Packard Tool Storage User Manual
Troubleshooting & Diagnostics 
Module Replacement Procedures 
70 
Troubleshooting 
DF Disk Module - Is the Volume Group or Physical Volume Group Active? (HP 9000 Series 
800 with Strict Mirroring) 
Use this procedure to determine if the volume group and physical volume group is active: 
1. At the host console type: 
# vgdisplay <VG name> 
If you followed the example under “Example of a Disk Module Failure”, the host will display: 
# vgdisplay /dev/vg00 
If the volume group is not active, the host will display: 
# vgdisplay: volume group not active 
# vgdisplay: cannot display volume group <VG name> 
2. If the disk was defective when vgchange was executed, the following messages will be displayed: 
VGDISPLAY:WARNING: COULDN'T QUERY PHYSICAL VOLUME “/DEV/DSK/c2t4d0” 
THE SPECIFIED PATH DOES NOT CORRESPOND TO PHYSICAL VOLUME 
ATTACHED TO THE VOLUME GROUP 
VGDISPLAY: WARNING: COULDN'T QUERY ALL OF THE PHYSICAL VOLUMES 
• If the message above displays, the physical volume is not active. Refer to “DF Disk Module 
Replacement/Recovery Procedure for Unattached Physical Volumes (HP 9000 Series 800 with 
Strict Mirroring)”. 
• If the message above does not display, the physical volume is active. Refer to “DF Disk Module -: 
Is the Physical Volume Attached? (HP 9000 Series 800 with Strict Mirroring)”. 