Specifications

Model 900 Accumulator
A
F
D
B
C
E
- Loosen the inflation screw (A) to
relieve nitrogen pressure.
- Drill the safety nylon plugs (B) to loosen
and remove the assembling screws (C).
- Clean the upper and lower
accumulator flanges (or the
accumulator cover and the back head).
- Clean diaphragm groove (D). Make sure
that bores are not plugged with rubber.
Clean if necessary.
- Check ring seat on upper flange. Only
perfect seat is acceptable.
- Clean and check all bolt threads in the
flange (or the back head).
- Clean and check all bolts.
- Install new diaphragm (E).
- Lubricate the diaphragm upper face with
silicon lubricant (Rhodorsyl).
- Install the upper flange. Grease the fix-
ing bolt (C) threads with a NLGI 2 grade
grease.
Do not use “MOLYKOTE 1000” grease
for this purpose.
- Dévissez la vis de gonflage (A) pour
décharger la pression d’azote.
- Percez les bouchons plastiques de sécurité
(B) et dévissez les vis
d’assemblage (C).
- Nettoyez les flasques supérieur et inférieur
(ou le coevercle et la tête arrière).
- Nettoyez la gorge de membrane (D). Véri-
fiez que les trous de la grille ne sont pas
obstrués par des débris de caoutchouc.
- Vérifiez la portée de la bague
d’étanchéité sur le flasque supérieur. Seule
une surface parfaite est admissible.
- Nettoyez et vérifiez les filetages du flasque
(de la tête arrière).
- Nettoyez et vérifiez toutes les vis.
- Montez une membrane neuve (E).
- Graissez la face supérieure de la
membrane avec un lubrifiant silicone
(Rhodorsyl).
- Montez le flasque supérieur. Graissez le filt-
age des vis d’assemblage (C) avec de la
graissw grade NLGI 2.
Ne pas utiliser de graisse “MOLYKOTE
1000” pour cette application.
2 RÉPARATION2 REPAIRING
2.1 2 Part Accumulators 2.1 Accumulateur en 2 parties
Page M9