Specifications
Model 900 Trouble Shooting
TECHNICAL PROBLEMS
Before looking for a hammer problem, look for a problem in the installation like bad quick couplers or a
plugged filter [see page M3 for how to check the installation].
Make sure that the hammer has not been hooked up backwards.
Make sure that the hammer has the proper tool.
Make sure that the down pressure has been applied.
Make sure that no valve(s) are closed.
For any other problem, refer to the Trouble Shooting page M1. If you cannot identify the problem, BEFORE
calling your TRAMAC dealer, collect the following information. A complete diagnosis cannot be done without
it.
Low Pressure Gauge 0-160 Psi
Return and Supply Lines (Same Size as Breaker)
Flow Meter
Flow Scale
Oil Temperature Gauge
Pressure Gauge
Needle Valve
Page M2
A. Flow rate in high pressure line running to the hammer at operating temperature and operating pressure.
B. Value of high pressure at hammer inlet when hammer is operating (use a 0-3000 psi gauge).
C. Value of back pressure in return line (use a 0-300 psi gauge).
D. Setting of relief valve in the system. For more details, please refer to page M3.