Technical data
5-6
9030140 Diagnostics
Power Supply LEDs
LED
Indication When
lit
Cure
DOORS
OPEN
Interface card cage door or processor Close door(sl, tighten thumbscrews.
stack
door
is
open. OV also lights.
STACK TEMP
Processor
stack temperature has ex-
Check ambient air temperature, airflow,
ceeded
lOO°e.
fans, power supply assembly.
SEC
BOARD
+ 12MM mass storage power supply Check + 12MM mass storage power
has failed or temperature
in
power supply
and
bus, ambient air tempera-
supply assembly has exceeded
100°e.
ture, airflow, fans, power supply
assembly.
PWR
Peak
primary current exceeded
9A.
Check power supply assembly, short
circuits.
OV
Used
in
conjunction with voltage LEOs:
Close door(s), tighten thumbscrews.
"on"
indicates an overvoltage condition Check power supply assembly, short or
on one or more
of
the supplies or door
open
circuits.
open.
"off'
indicates an undervoltage
condition.
-19
Fault condition exists on the indicated Check power supply assembly, lOP
-12
supply. If the OV LED
is
also
lit,
an
bus, modules using the indicated vol-
-2
overvoltage condition
is
indicated:
if
OV
tage, short or
open
circuits.
3
is
not
lit.
an undervoltage condition
is
5 indicated.
6
12
19
System
Functional Tests (SFT)
1.
If
not
previously done. install and verify the HP-UX operating system.
2.
In
response to the
log
in:
prompt, type:
roo
t
and
press (
RETURN).
You are now the
super-user.
3. Type:
cd
Ius
r/ptests.
4. Type: s
tar
t
and
press (
RETURN).
5.
From the
menu
that appears
on
the system console, select the test you would like to run,
enter its number,
and
press (
RETURN).