Technical data

2-6 9020/9030/9040 Environmental/Installation/PM
RAM/CPU Finstrate Installation
1.
(ALL)
TURN
THE
POWER OFF AND DISCONNECT THE POWER CORD.
2.
(520)
Open
the left door.
(530)
Remove
the
front panel.
(540)
Remove
the
front
bottom
panel.
3.
(530/540 ONLY)
From
the
front of the computer, remove the Radio Frequency Interference
(RFI)
shield by
loosening
the
six thumbscrews.
4.
(ALL)
Open
processor stack door.
5.
(ALL)
CAUTION
ELECTROSTATIC DISCHARGE DAMAGE CAN OCCUR IN THE
FOLLOWING
STEPS.
FOLLOW
THE PRECAUTIONS IN CHAPTER
4 OF
THE
SERVICE MANUAL.
DO
NOT
TOUCH
EDGE CONNECTOR OR FINSTRATE PLANE.
HOLD
FINSTRATE BY EJECTORS OR SIDE EDGES ONLY. HAND-
LING
FINSTRATE
INCORRECTLY
COULD
CAUSE
ELECTROSTATIC DISCHARGE DAMAGE.
WHEN
INSTALLING
FINSTRATE,
HOLD
BY EJECTORS AND MOVE AIR CONTROLLER
OUT
OF THE
WAY
WITH
THE SIDE EDGE OF THE FINSTRATE.
Install
the
finstrate
in
the
first
unoccupied slot from the bottom. DO NOT LEAVE EMPTY
SLOTS
BETWEEN FINSTRA TES.
6.
(ALL)
Close
the
processor stack door. Firmly tighten thumbscrews to prevent
RFI
radiation.
Replace
the
label that
is
used as a seal for the processor stack
door
(Part
Number
5180-5201).
7.
(530/540 ONLY)
Replace RFI shield.
8.
(520)
Close left door.
(530)
Replace front panel.
(540)
Replace
the
front
bottom
panel.
9.
(ALL)
Connect
power
cord
to
ac outlet.