Technical data
Introduction to nPartitions
Specifying Cells and I/O Chassis to Commands
HP System Partitions Guide: Administration for nPartitions—rp7410
EMSP—schwartz@rsn.hp.com
73
On HP Superdome servers, the chassis number is:
— 1 — Chassis 1, the left chassis in the bay, as viewed when facing
the bay/chassis.
— 3 — Chassis 3, the right chassis in the bay, as viewed when facing
the bay/chassis.
In HP Superdome servers all chassis are 12-slot I/O chassis, both in
Compute cabinets and in I/O Expansion cabinets.
The example below shows the parstatus command listing details about
two different I/O chassis (cabinet 0/bay 0/chassis 1, and cabinet 0/bay
1/chassis 3).
Use the parstatus -I command to list all I/O chassis within a server
complex, regardless of the chassis cell connections and partition
assignments.
Use the rad -q command to list the currently available PCI I/O slots in
the local partition and their status.
In the following example, both the parstatus and rad commands show
details for various chassis and slots, including chassis 0/1/3.
# parstatus -i0/0/1
[Chassis]
Core Connected Par
Hardware Location Usage IO To Num
=================== ============ ==== ========== ===
cab0,bay0,chassis1 absent - - -
# parstatus -i0/1/3
[Chassis]
Core Connected Par
Hardware Location Usage IO To Num
=================== ============ ==== ========== ===
cab0,bay1,chassis3 active yes cab0,cell0 0
#
HP Restricted / DRAFT
DRAFT NOV 2001