Technical data

Listing and Managing Server Hardware
Checking for Processor Failures
HP System Partitions Guide: Administration for nPartitions—rp7410
EMSP—schwartz@rsn.hp.com
304
Checking for Processor Failures
You can list cell processor configuration, including any processor failures,
using software tools and utilities.
You can perform this procedure using the following methods:
HP-UX Commands on page 304
This procedure (parstatus -V -c#) lists a cell’s processor status,
including any failures, from HP-UX.
Partition Manager on page 305
This procedure (Cell —> Show Cell Details menu, CPUs/Memory tab)
lists processor details and any failures using Partition Manager.
HP-UX Commands This procedure (parstatus -V -c
#
) lists a cell’s processor status,
including any failures, from HP-UX.
Step 1. Log in to HP-UX running on any of the system’s partitions.
You can check processor details for any cell from any partition.
Step 2. Issue the parstatus -V -c
#
command to list detailed information
about the specified cell (-c
#
).
The detailed information parstatus reports includes a list of all
processors (CPUs) installed on the cell, and the status of each CPU.
HP Restricted / DRAFT
DRAFT NOV 2001