267
# parstatus -V -b0
[Cabinet]
Cabinet I/O Bulk Power Backplane
Blowers Fans Supplies Power Boards
OK/ OK/ OK/ OK/
Cab Failed/ Failed/ Failed/ Failed/
Num Cabinet Type N Status N Status N Status N Status GSP
=== ============ ========= ========= ========== ============ ======
0 SD32000 4/ 0/ N+ 5/ 0/ ? 5/ 0/ N+ 3/ 0/ N+ active
Bulk Power Supplies(BPS)
========================
Power Supply 0 ok
Power Supply 1 ok
Power Supply 2 ok
Power Supply 3 ok
Power Supply 4 ok
Backplane Power Boards
======================
Power Supply 0 ok
Power Supply 1 ok
Power Supply 2 ok
Notes: N+ = There are one or more spare items (fans/power supplies).
N = The number of items meets but does not exceed the need.
N- = There are insufficient items to meet the need.
? = The adequacy of the cooling system/power supplies is unknown.
# frupower -d -C
Global cell 0; cabinet 0, cell 0 is powered on.
Global cell 2; cabinet 0, cell 2 is powered on.
Global cell 4; cabinet 0, cell 4 is powered on.
Global cell 6; cabinet 0, cell 6 is powered off.
# frupower -d -c4
Global cell 4; cabinet 0, cell 4 is powered on.
# frupower -d -I
Cabinet 0, bay 0, chassis 1 is powered on.
Cabinet 0, bay 0, chassis 3 is powered on.
Cabinet 0, bay 1, chassis 1 is powered off.
Cabinet 0, bay 1, chassis 3 is powered on.
# frupower -d -i0/1/3
Cabinet 0, bay 1, chassis 3 is powered on.
# rad -q
Driver(s)
Slot Path Bus Speed Power Occupied Suspended Capable
0-0-1-0 0/0/0 0 33 On Yes No No
0-0-1-1 0/0/1/0 8 33 On No N/A N/A
0-0-1-2 0/0/2/0 16 33 On Yes No Yes
0-0-1-3 0/0/3/0 24 33 On No N/A N/A
0-0-1-4 0/0/4/0 32 33 On No N/A N/A
0-0-1-5 0/0/6/0 48 33 On No N/A N/A
0-0-1-6 0/0/14/0 112 33 On Yes No Yes
Cabinet Power
Cell Power
I/O Chassis Power
PCI Slot Power
HP Restricted / DRAFT