Technical data
Listing and Managing Server Hardware
Determining Hardware Power Status
HP System Partitions Guide: Administration for nPartitions—rp7410
EMSP—schwartz@rsn.hp.com
263
Determining Hardware Power Status
You can use system software to check power status for the following
components from remote locations:
• Cabinets
• Bulk Power Supplies and Power Boards
• Cell Boards
• I/O Chassis
• Individual PCI Slots
NOTE Cabinet power details and power supply details are specific to each
server model. For example, HP Superdome servers and HP rp8400 server
have different power configurations and requirements.
You can perform these procedures using the following methods:
• Service Processor (GSP or MP) on page 264
This procedure (Command menu, PS command) checks power status
for cabinets, bulk power supplies and power boards, cells, and core I/O
using the service processor.
• HP-UX Commands on page 265
This procedure (parstatus -B, parstatus -V -b#, frupower -d -C,
frupower -d -I, or rad -q) checks the power status for system hardware
from HP-UX.
• Partition Manager on page 268
This procedure (Complex —> Show Complex Details menu) lists
system hardware power status using Partition Manager.
HP Restricted / DRAFT
DRAFT NOV 2001