Technical data

Procedures for Managing nPartitions
Adding Cells to an nPartition
HP System Partitions Guide: Administration for nPartitions—rp7410
EMSP—schwartz@rsn.hp.com
215
HP-UX Commands This procedure (using the parstatus and parmodify commands) adds
cells to an nPartition using HP-UX commands.
Step 1. Use the parstatus -A -C command to list all available cells (the
unassigned cells) in the server complex.
Step 2. Choose one or more eligible cells from the list to add to the nPartition.
Adding the cell(s) to the nPartition should create a configuration that
adheres to the hardware requirements and performance guidelines.
Step 3. Modify the nPartition by issuing the parmodify -p# -a#... command
to add the cell.
The -p
#
option specifies the partition number (
#
) for the nPartition being
modified.
The -a
cell
:
type
:
use
:
fail
option specifies the cell ID and other details
for the cell to be added to the nPartition.
To add multiple cells you can specify the -a option multiple times in the
same command.
For example: parmodify -p1 -a0:base:y:ri -a2:base:y:ri adds two
cells (cell ID 0 and cell ID 2) to nPartition number 1.
The -a option (-a
cell
:
type
:
use
:
fail
) specifies the following details
for each cell that you add to the nPartition.
cell
The cell to be added to the nPartition. You can
specify the cell in global (cell) format or in hardware
location (cabinet/slot) format.
type
The cell type: base is the only supported cell type
and it is the default.
use
The cell’s use-on-next-boot value: y or n. Use y (the
default) if the cell is to be an active member of the
partition, or use n if the cell is to remain an inactive
member.
fail
The cell’s failure usage: ri (reactivate with
interleave) is the only supported failure usage
policy and it is the default.
You can optionally specify the parmodify command’s -B option to require
that the modified partition be rebooted.