For system alerts of levels 3-5, the attention condition on the LED can be cleared by accessing the logs using
the sl command available in the management processor command mode.
The fault condition for system alerts of level 7 can be cleared by resolving the problem and cycling power.
Refer to the SL error logs for additional error information.
NOTE Always check the management processor status logs in the case of a blinking yellow or red
system LED before replacing any hardware.
Blinking green Booting or running BCH.
Blinking yellow (1/sec.) Attention:
Alerts of levels 3-5 detected in the management processor logs
The LED will turn off once the event log has been read.
Blinking red (2/sec.) Fault:
System Alert 7 Detected, LED will blink until the problem is resolved
and the system boots successfully
Fatal hardware error detected by BMC, LED will blink until problem is
corrected.
Table 4-3 System LED States (Continued)
System LED State