Owner manual

48
The Switch data window fields are described in Table 8.
Table 8 Switch data window fields
Field Description
Summary Group
Switch Type Switch model
First Port Address Switch Fibre Channel address
World Wide Name Switch world wide name
Serial Number Number assigned to each chassis.
Reason for Status The reason for the operational state.
Vendor Switch manufacturer
MAC Address Media Access Control address
Negotiated Domain ID The domain ID currently being used by the fabric
Configured Domain ID The domain ID, defined by network administrator
Domain ID Lock Domain ID lock status. Prevents (True) or permits (False) dynamic
domain ID reassignment.
Number of Ports Number of physical ports on the switch
Operational State Switch operational state: Online, Offline, Diagnostic, Down
Administrative State Current switch administrative state
Configured Admin State Administrative state that is stored in the switch configuration
Beacon Status Beacon status. Switch LEDs are blinking (On) or not blinking (Off).
Status Group
Operational State Switch operational state: Online, Offline, Diagnostic, Down
Administrative State Current switch administrative state
Configured Admin State Administrative state that is stored in the switch configuration
Beacon Status Beacon status. Switch LEDs are blinking (On) or not blinking (Off).
Reason for Status The reason for the operational state.
Temperature Internal switch temperature °C
Power Supply 1 Status Power Supply 1 Status
Temperature Failure Port
Shutdown
Non-configurable (always enabled for this switch). All ports are shut
down when the switch temperature exceeds the Failure Temperature.
Warning Temperature Non-configurable temperature threshold, above which a warning
condition alarm is generated.
Failure Temperature Non-configurable temperature threshold, above which a failure
condition alarm is generated.
POST Status The current diagnostic state of the switch.
POST Fault Code The code value for the last recorded diagnostic test result recorded on
the switch.
Test Status The current diagnostic test status of switch.