Specifications

DESCRIPTION AND OPERATION Document No. DER01120
Effective Date 25 May 07 Page 9 of 9
Vibration
Tripping the vibration switch due to excessive vibration of the centrifuge will also cause a
shutdown, as the switch interrupts power flow to centrifuge run relay CR1. After removing the
cause of unusual vibration, pressing the external button on the switch housing returns the switch
contacts to the magnetically latched condition to restore power. The centrifuge is re-started by
pressing the CENTRIFUGE ON button.
Motor Over-Temperature
The motor over-temperature switch interrupts power to run relay CR1 if the drive motor becomes
excessively heated. After allowing the motor to cool and removing the cause of heating, the
centrifuge is re-started by pressing the CENTRIFUGE ON button.