Figure 19. Installing Backup Module and Interface Module
Instructions for Installing the Backup Module
1 Remove power from the unit.
2 If the interface module is already installed in the ProCurve Secure Router chassis, remove all
connected cables, release the screws at both edges of the interface module front panel, and
slide the module out of the chassis.
3 Carefully align the P1 connector on the interface module with the J1 connector on the backup
module. Using only fingertip pressure so that neither circuit board bends or flexes, ensure that
the connectors are firmly seated. Secure the backup module to the interface module using the
screws and standoff posts supplied. (See Figure 19.)
4 Slide the interface module with the backup module attached into the ProCurve Secure Router
chassis, continuing with the normal interface module installation.
Instructions for Installing the Interface Modules and Wide Modules
1 Remove power from the unit.
2 Slide the option module into the option slot until the module is firmly seated against the chassis.
(See Figure 19.)
3 Secure the screws at both edges of the module.
4 Connect the cables to the associated device(s).
5 Restore power to the unit.