Installation Manual

Unit Installation ProCurve Secure Router Installation Guide
38 Copyright 2006 Hewlett-Packard Development Company, LP 5990-3760
Figure 18. Grounding the ProCurve Secure Router
Grounding Requirements Statement
A supplementary equipment grounding conductor shall be installed between the product or system and
ground that is in addition to the equipment grounding conductor in the power supply cord. The supplementary
equipment grounding conductor shall not be smaller in size than the ungrounded branch-circuit supply
conductors. The supplementary equipment grounding conductor shall be connected to the product at the
terminal provided, and shall be connected to ground in a manner that will retain the ground connection when
the product is unplugged from the receptacle. The connection to ground of the supplementary equipment
grounding conductor shall be in compliance with the rules for terminating bonding jumpers at Part K or
Article 250 of the National Electrical Code, ANSI/NFPA 70. Termination of the supplementary equipment
grounding conductor is permitted to be made to building steel, to a metal electrical raceway system, or to any
grounded item that is permanently and reliably connected to the electrical service equipment ground.
The supplemental grounding conductor shall be connected to the equipment using a number 8 ring terminal and
should be fastened to the grounding terminal provided on the rear panel of the equipment. The ring terminal
should be installed using the appropriate crimping tool (AMP P/N 59250 T-EAD crimping tool or equivalent).
Installing Interface and Backup Modules
The backup modules plug on to the interface modules. The interface modules are then installed in the front
panel option module slot. The following tables list the installation steps. See Figure 19 on page 39.
Caution
Always remove power from the unit prior to removing or installing a module.
Improper installation may result in damage to the modules.
Warning
For ProCurve Secure Router modules with outside plant connections, ensure that all
cables are removed from the module before installing or removing it from the router
chassis.