Installation Manual
ProCurve Secure Router Installation Guide Option Modules
5990-3760 Copyright 2006 Hewlett-Packard Development Company, LP 31
Diagnostics
• Network Loopbacks: Line, payload, remote
• Test Pattern Generation and Detection: QRSS, 2
15
- 1, 511, all ones, all zeros
Compliance
• ACIF S016, ETSI TBR 12/TBR 13, ACTA/FCC Part 68, IC CS-03
• UL/CUL 60950, EN 60950, IEC 60950, AS/NZS 60950
• EMC - see Electromagnetic Compatibility (EMC) Table on page 62.
Environmental
• Operating Temperature: 0°C to 50°C (32°F to 122°F)
• Non-Operating Temperature: -20°C to 70°C (-4°F to 158°F)
• Relative Humidity: 95 percent noncondensing at 30°C (86°F)
• Non-Operating Relative Humidity: 95 percent noncondensing at 30°C (86°F)
• Altitude: Up to 3.05 km (10,000 ft)
Physical
• 14.29 cm (5.63 in) W x 21.91 cm (8.63 in) D
Note
No external CSU/DSU is needed with the T1/FT1 or E1/FE1 interface.