Installation Manual

ProCurve Secure Router Installation Guide Option Modules
5990-3760 Copyright 2006 Hewlett-Packard Development Company, LP 29
2xISDN BRI U Interface Module
The 2xISDN BRI U Interface Module (see Figure 15) adds ISDN BRI (with U interface) capability to the
ProCurve Secure Router. Refer to Table A-11 on page 46 for the pinouts. Refer to Table A-12 on page 47
for the backup connector pinouts. An optional backup module is required for backup applications.
Figure 15. 2xISDN BRI U Interface Module
Features and Specifications
Operating Mode
Independent TE mode of operation for each
interface
Features
Line Rate: Network support for 128 kbps
(2 B channels per interface)
Switch Compatibility: Euro-ISDN
Test Capability: Local and network
loopbacks
Compliance
EN 60950, IEC 60950
EMC - see Electromagnetic Compatibility
(EMC) Table on page 62
Physical
Dimensions: 6.99 cm (2.75 in) W x
10.80 cm (4.25 in) D
Environmental
Operating temperature: 0°C to 50°C (32°F
to 122°F)
Non-Operating Temperature: -20°C to
70°C (-4°F to 158°F)
Relative Humidity: Up to 95 percent
noncondensing at 30°C (86°F)
Non-Operating Relative Humidity: Up to
95 percent noncondensing at 30°C (86°F)
Altitude: Up to 3.05 km (10,000 ft)