Installation Manual

ProCurve Secure Router Installation Guide Option Modules
5990-3760 Copyright 2006 Hewlett-Packard Development Company, LP 23
1xE1 + G.703 Drop and Insert Interface Module
The 1xE1 + G.703 Drop and Insert Interface Module (see Figure 9) provides a single E1 interface
(2.043 Mbps) with user-selectable TS0 assignment and a G.703 drop port which may be used to drop and
insert traffic to an E1 PBX. Refer to Table A-4 on page 44 for the E1 pinouts. Refer to Table A-6 on page 45
for the G.703 pinouts. Refer to Table A-12 on page 47 for the backup connector pinouts. An optional backup
module is required for backup applications.
Figure 9. 1xE1 + G.703 Drop and Insert Interface Module
Features and Specifications
Operating Modes
E1/ FE1 Frame Relay/Multilink Frame Relay
E1/FE1 PPP/Multilink PPP
E1/FE1 HDLC
E1 Interface
Supported Standards: ITU-T G.703,
ITU-T G.704 (CRC-4), ITU-T G.797,
ITU-T G.823
Line Rate: 2.048 Mbps +
50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
FE1 Line Rate: Channelized timeslot
(in multiples of 56/64 kbps)
Receiver Sensitivity: -30 dB
Connector: RJ-48C
G.703 Interface
Line Interface: Per ITU-T G.703
Line Rate: 2.048 Mbps ± 50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
Capacity: 1 to 31 timeslots
Receiver Sensitivity: -30 dB
Connector: RJ-48C
Clock Source
•Network
•Internal
Through
Diagnostics
Test Pattern Generation and Detection:
QRSS, 511, all ones, all zeros
Network loopbacks
Alarm generation and detection
Network performance data (15 minutes and
24 hours)
Compliance
ACIF S016, ETSI TBR 12/TBR 13
EN 60950, AS/NZS 60950
EMC - see Electromagnetic Compatibility
(EMC) Table on page 62
Environmental
Operating temperature: 0°C to 50°C (32°F
to 122°F)
Non-Operating Temperature: -20°C to
70°C (-4°F to 158°F)
Relative Humidity: Up to 95 percent
noncondensing at 30°C (86°F)
Non-Operating Relative Humidity: Up to
95 percent noncondensing at 30°C (86°F)
Altitude: Up to 3.05 km (10,000 ft)
Physical
Dimensions: 6.99 cm (2.75 in) W x
10.80 cm (4.25 in) D