Installation Manual
Option Modules ProCurve Secure Router Installation Guide
22 Copyright 2006 Hewlett-Packard Development Company, LP 5990-3760
1xE1 Interface Module
The 1xE1 Interface Module (see Figure 8) provides an E1 interface for the ProCurve Secure Router meeting
the requirements of ITU-T G.703/G.704. The module provides a single 2.048 Mbps network interface. Refer
to Table A-4 on page 44 for the pinouts. Refer to Table A-12 on page 47 for the backup connector pinouts.
An optional backup module is required for backup applications.
Figure 8. 1xE1 Interface Module
Features and Specifications
Operating Modes
• E1/ FE1 Frame Relay/Multilink Frame Relay
• E1/FE1 PPP/Multilink PPP
• E1/FE1 HDLC
E1 Interface
• Supported Standards: ITU-T G.703,
ITU-T G.704 (CRC-4), ITU-T G.797,
ITU-T G.823
• Line Rate: 2.048 Mbps +
50 PPM
• Line Code: AMI or HDB3
• Framing: FAS with optional CRC-4
• FE1 Line Rate: Channelized timeslot
(in multiples of 56/64 kbps)
• Receiver Sensitivity: -30 dB
• Connector: RJ-48C
Clock Source
•Network
• Internal
Diagnostics
• Test Pattern Generation and Detection: QRSS,
511, all ones, all zeros
• Network loopbacks
• Alarm generation and detection
• Network performance data (15 minutes and
24 hours)
Compliance
• ACIF S016, ETSI TBR 12/TBR 13
• EN 60950, IEC 60950, AS/NZS 60950
• EMC - see Electromagnetic Compatibility
(EMC) Table on page 62
Environmental
• Operating Temperature: 0°C to 50°C (32°F
to 122°F)
• Non-Operating Temperature: -20°C to 70°C
(-4°F to 158°F)
• Relative Humidity: Up to 95 percent
noncondensing at 30°C (86°F)
• Non-Operating Relative Humidity: Up to
95 percent noncondensing at 30°C (86°F)
• Altitude: Up to 3.05 km (10,000 ft)
Physical
• Dimensions: 6.99 cm (2.75 in) W x
10.80 cm (4.25 in) D