Installation Manual
ProCurve Secure Router Installation Guide Option Modules
5990-3760 Copyright 2006 Hewlett-Packard Development Company, LP 21
2xT1 Interface Module
The 2xT1 Interface Module (see Figure 7) provides two T1 interfaces for the ProCurve Secure Router. The
module provides up to 1.544 Mbps on each network interface. Refer to Table A-3 on page 44 for the
pinouts. Refer to Table A-12 on page 47 for the backup connector pinouts. An optional backup module is
required for backup applications.
Figure 7. 2xT1 Interface Module
Note
The 2xT1 module supports a single clock source for both T1 interfaces. Changing the
clock source on one T1 interface automatically affects the configuration of the other T1
interface. For example, setting the clock to line on the first T1 configures the clock source
of the second T1 as through.
F
eatures and Specifications
Operating Modes
• T1/ FT1 Frame Relay/Multilink Frame Relay
• T1/FT1 PPP/Multilink PPP
• T1/FT1 HDLC
T1 Interface
• Supported Standards: AT&T TR 62411,
AT&T TR 54016, Bellcore TR 194,
ANSI T1.403
• Line Rate: 1.544 Mbps +
75 bps
• Line Code: AMI or B8ZS
• Framing: D4 (SF) or ESF
• FT1 Line Rate: DS0 channelized
• Input Signal: 0 to -36 dB (DS1)
• Line Build-Out: 0, -7.5, -15, -22.5 dB
• Connector: RJ-48C
• DS0 Assignment: Programmable
Clock Source
•Network
•Internal
• Through
Physical
• Dimensions: 6.99 cm (2.75 in) W x
10.80 cm (4.25 in) D
Diagnostics
• Test Pattern Generation and Detection:
QRSS, 511, 2
15
-1, 2
20
-1, all ones, all zeros
• Network loopbacks (local and remote);
responds to both inband and FDL loop code
s
(T1 interface only)
• Alarm generation and detection
• Network performance data (15 minutes an
d
24 hours)
Compliance
• ACTA/FCC Part 68, IC CS-03
• UL/CUL 60950, IEC 60950
• EMC - refer to Electromagnetic
Compatibility (EMC) Table on page 62.
Environmental
• Operating Temperature: 0°C to 50°C (32°
F
to 122°F)
• Non-Operating Temperature: -20°C to 70°
C
(-4°F to 158°F)
• Relative Humidity: Up to 95 percent
noncondensing at 30°C (86°F)
• Non-Operating Relative Humidity: Up to
95 percent noncondensing at 30°C (86°F)
• Altitude: Up to 3.05 km (10,000 ft)