Installation Manual
Option Modules ProCurve Secure Router Installation Guide
20 Copyright 2006 Hewlett-Packard Development Company, LP 5990-3760
1xT1 + DSX-1 Interface Module
The 1xT1 + DSX-1 Interface Module (see Figure 6) provides a full T1 or fractional T1 network interface and
a DSX-1 interface. Refer to Table A-3 on page 44 for the T1 connector pinouts, Table A-5 on page 44 for the
DSX-1 connector pinouts, and Table A-12 on page 47 for the backup connector pinouts. An optional backup
module is required for backup applications.
Figure 6. 1xT1 + DSX-1 Interface Module
Features and Specifications
Operating Modes
• T1/FT1 Frame Relay/Multilink Frame Relay
• T1/FT1 PPP/Multilink PPP
• T1/FT1 HDLC
T1/FT1 Interface
• Supported Standards: AT&T TR 62411,
AT&T TR 54016, Bellcore TR 194,
ANSI T1.403
• Line Rate: 1.544 Mbps +
75 bps
• Line Code: AMI or B8ZS
• Framing: D4 (SF) or ESF
• FT1 Line Rate: DS0 channelized (multiples
of 56/64 kbps)
• Input Signal: 0 to -36 dB (DS1)
• Line Build-Out: 0, -7.5, -15, -22.5 dB (long)
or 0 to 655 feet (short)
• Connector: RJ-48C
• DS0 Assignment: Programmable
DSX-1 Interface
• Line Interface: DSX-1 per ANSI T1.102
• DSX Receiver Input Range: -10 dBdsx to +6
dBdsx
• Line Rate: 1.544 Mbps
• Capacity: 1 to 24 DS0s
• Line Codes: AMI, B8ZS
• Framing: D4 (SF) or ESF
• Line Length: 0 to 655 feet and -7.5 dB
• Connector: RJ-48C
• DSX-1 interface to PBX
Clock Source
•Network
• Internal
• Through
Physical
• Dimensions: 6.99 cm (2.75 in) W x
10.80 cm (4.25 in) D
Diagnostics
• Test Pattern Generation and Detection: 511,
QRSS, all ones, all zeros
• Network loopbacks (local and remote);
responds to both inband and FDL loop
codes (T1 interface only)
• Alarm generation and detection
• Network and user sets of performance data
(15 minutes and 24 hours)
Compliance
• ACTA/FCC Part 68, IC CS-03
• UL/CUL 60950, IEC 60950
• EMC - see Electromagnetic Compatibility
(EMC) Table on page 62
Environmental
• Operating Temperature: 0°C to 50°C (32°F
to 122°F)
• Non-Operating Temperature: -20°C to 70°C
(-4°F to 158°F)
• Relative Humidity: Up to 95 percent
noncondensing at 30°C (86°F)
• Non-Operating Relative Humidity: Up to
95 percent noncondensing at 30°C (86°F)
• Altitude: Up to 3.05 km (10,000 ft)