Command Reference Guide
SROS Command Line Interface Reference Guide Frame Relay Sub-Interface Config Command Set
5991-2114 © Copyright 2005 Hewlett-Packard Development Company, L.P. 597
backup connect-timeout <seconds>
Use the backup connect-timeout command to specify the number of seconds to wait for a connection
after a call is attempted before trying to call again or dialing a different number. It is recommended this
number be greater than 60.
Syntax Description
<seconds> Selects the amount of time in seconds that the router will wait for a connection
before attempting another call (valid range: 10 to 300)
Default Values
<seconds> 60 seconds
Command Modes
(config-fr 1.16)# Virtual Frame Relay Sub-Interface Configuration Mode
(config-atm 1.1)# ATM Sub-Interface Configuration Mode
Usage Examples
The following configures the Secure Router OS to wait 120 seconds before retrying a failed backup call:
(config)#interface atm 1.1
(config-atm 1.1)#backup connect-timeout 120