frame-relay lmi-t391dte <seconds>
Use the frame-relay lmi-t391dte command to set the T391 signal polling timer for the DTE endpoint.
Typical applications should leave the default value for this timer. Use the no form of this command to
return to the default value.
Syntax Description
<seconds> Sets the timer value in seconds (valid range: 5-30)
Default Values
<seconds> 10 seconds
Command Modes
(config-fr 1)# Virtual Frame Relay Interface Configuration Mode required
Functional Notes
The T391 timer sets the time (in seconds) between polls to the Frame Relay network.
Usage Examples
The following example sets the T391 timer for 15 seconds:
(config)#interface frame-relay 1
(config-fr 1)#frame-relay lmi-t391dte 15