Operating instructions

32
APPENDIX B
AC POWER
AC power connector 250 V NEMA L6-20 (twist lock), IEC 309 male inlet, PowerCon, or VEAM
Voltage selection Automatic, two ranges, each with high-low voltage tap �
Safety agency rated
operating voltage
95 V AC - 125 V AC; 208 V AC - 235 V AC; 50/60 Hz
Turn on/turn off points 85 V AC - 134 V AC; 165 V AC - 264 V AC; 50/60 Hz
Current Draw
Idle current 0.64 A rms (115 V AC); 0.32 A rms (230 V AC); 0.85 A rms (100 V AC)
Max. long-term continuous
current (>10 sec)
8.8 A rms (115 V AC); 4.4 A rms (230 V AC); 10 A rms (100 V AC)
Note: Measured using pink noise as an input signal.
Burst Current (<1 sec) 19 A rms (115 V AC); 9.5 A rms (230 V AC); 22 A rms (100 V AC)
Note: AC power cabling must be of sufficient gauge so that under burst current rms
conditions, cable transmission losses do not drop voltage below specified operating range
at the speaker.
Ultimate Short-Term Peak
Current Draw
39 A pk (115 V AC); 20 A pk (230 V AC); 45 A pk (100 V AC)
Inrush Current 7 A pk (115 V AC); 7 A pk (230 V AC); 10 A pk (100 V AC)
RMS NETWORK (Standard with rigging version and optional with others)
Equipped for two-conductor twisted-pair network, reporting all operating parameters of
amplifiers to system operator’s host computer.
PHYSICAL
Enclosure Premium birch plywood
Finish Black textured
Protective grille Perforated metal grille lined with acoustical black mesh
Dimensions 41.4” w x 22.5” h x 22” d (1052 mm x 572 mm x 559 mm)
Weight 182 lb (82.55 kg); with rigging 215 lb (97.52 kg)
Rigging Optional end-mounted QuickFly rigging hardware, with captive GuideALinks and quick-
release pins; compatible with MICA compact highpower curvilinear array loudspeakers and
accessories
43.87
[1114.37 mm]
41.40
[1051.56 mm]
22.97
[583.51 mm]
22.50
[571.44 mm]
22.00
[558.75 mm]
11.25
[285.72 mm]
15.08
[382.93 mm]
6.90
[175.22 mm]
18.46
[468.84 mm]
10.50
[266.70 mm]
12.00