Item
HP
5920AF-24XG/HP
5920AF-24XG
TAA
HP
5900AF-48XG-4Q
SFP+/HP
5900AF-48XG-4Q
SFP+ TAA/HP
5900CP-48XG-4Q
SFP+/ HP
5900CP-48XG-4Q
SFP+ TAA/HP
5900CP-48XG-4Q
SFP+8Gb FC B-F
HP
5900AF-48G-4XG
-2QSFP+/HP
5900AF-48G-4XG
-2QSFP+ TAA
HP
5900AF-48XGT-4
QSFP+/HP
5900AF-48XGT-4
QSFP+ TAA
DC-input
voltage
• Rated voltage:
–40 VDC to –60
VDC
• Max voltage:
–40 VDC to –72
VDC
• Rated voltage:
–40 VDC to –60
VDC
• Max voltage:
–40 VDC to –72
VDC
• Rated voltage:
–40 VDC to –60
VDC
• Max voltage:
–40 VDC to –72
VDC
• Rated voltage:
–40 VDC to –60
VDC
• Max voltage:
–40 VDC to –72
VDC
Minimum
power
consumption
• Single AC input:
334 W
• Dual AC inputs:
343 W
• Single DC input:
333 W
• Dual DC inputs:
339 W
• Single AC input:
183 W
• Dual AC inputs:
200 W
• Single DC input:
182 W
• Dual DC inputs:
197 W
• Single AC input:
98 W
• Dual AC inputs:
115 W
• Single DC input:
95 W
• Dual DC inputs:
11 0 W
• Single AC input:
124 W
• Dual AC inputs:
139 W
• Single DC input:
121 W
• Dual DC inputs:
133 W
Maximum
power
consumption
• Single AC input:
357 W
• Dual AC inputs:
366 W
• Single DC input:
360 W
• Dual DC inputs:
366 W
• AC: 257 W
• DC: 250 W
• Single AC input:
157 W
• Dual AC inputs:
175 W
• Single DC input:
151 W
• Dual DC inputs:
169 W
• Single AC input:
446 W
• Dual AC inputs:
455 W
• Single DC input:
444 W
• Dual DC inputs:
444 W
Chassis
leakage
current
compliance
• UL60950-1
• EN60950-1
• IEC60950-1
• GB4943
• UL60950-1
• EN60950-1
• IEC60950-1
• GB4943
• UL60950-1
• EN60950-1
• IEC60950-1
• GB4943
• UL60950-1
• EN60950-1
• IEC60950-1
• GB4943
Melting
current of
power supply
fuse
• 10 A @ 250 VAC
• 30 A @ 250 VDC
• 10 A @ 250 VAC
• 30 A @ 250
VDC
• 10 A @ 250 VAC
• 30 A @ 250
VDC
• 10 A @ 250 VAC
• 30 A @ 250 VDC
Operating
temperature
0°C to 45°C (32°F to
113°F)
0°C to 45°C (32°F to
113°F)
0°C to 45°C (32°F to
113°F)
0°C to 45°C (32°F to
113°F)
Operating
humidity
10% to 90%,
noncondensing
10% to 90%,
noncondensing
10% to 90%,
noncondensing
10% to 90%,
noncondensing
Fire resistance
compliance
• UL60950-1
• EN60950-1
• IEC60950-1
• GB4943
• UL60950-1
• EN60950-1
• IEC60950-1
• GB4943
• UL60950-1
• EN60950-1
• IEC60950-1
• GB4943
• UL60950-1
• EN60950-1
• IEC60950-1
• GB4943