Datasheet
HP Power Distribution
Units
Monitored PDUs
HP Monitored Power Distribution Unit: Full Rack Version
HP 8.6 kVA S1324 Monitored PDU- single input, 3Ø, 24A (NA/JPN)
AF504A
HP 8.3 S1140 Monitored PDU- single input, 1Ø, 40A (NA/JPN)
AF506A
HP 11 kVA S1316 Monitored PDU- single input, 3Ø, 16A (INTL)
AF508A
HP 7.3 kVA S1132 Monitored PDU- single input, 1Ø, 32A (INTL)
AF510A
HP Monitored Power Distribution Unit: Half Rack Version
HP 4.9 kVA S124 Monitored PDU- single input, 1Ø, 24A (NA/JPN)
AF914A
HP 7.3 kVA S132 Monitored PDU- single input, 1Ø, 32A (INTL)
AF915A
NOTE:
Please see the QuickSpecs for Technical Specifications and additional
information:
http://h18000.www1.hp.com/products/quickspecs/12118_div/12118_div.html
Modular PDUs 1U/0U
NOTE:
1U/0U mounting brackets shipped with the unit (optimized for 10000 G2
and 9000 series racks).
3.6kVA Model - mPDU, 16A, High (WW)
252663-B24
4.9kVA Model - mPDU, 24A, High (NA/JPN)
252663-D72
7.3kVA Model - mPDU, 32A, High (INT'L)
252663-B31
8.3kVA Model - mPDU, 40A, High (power cord attached) (NA/JPN)
252663-D73
NOTE:
For additional information on HP Power Distribution Units including
accessories please go to:
www.hp.com/go/pdu
.
NOTE:
Please see the UPS and PDU cable matrix's on the HP Power Protection
and Management page. Under Power Cords, click on the "HP Power Cord
Matrix" link. That link will list cable descriptions, requirements, and specifications
for UPS and PDU units. Please see the following link:
www.hp.com/products/powercords
.
HP Rack Series
HP Rack 10000 G2 Series
(Carbon/Graphite Metallic)
HP 10642 G2 Pallet Universal Rack
AF001A
HP 10642 G2 Shock Universal Rack
AF002A
HP 10642 G2 1200mm deep Shock Rack
AF092A
HP 10647 G2 1200mm deep Shock Rack
AF094A
NOTE:
It is mandatory to use a shock pallet when shipping racks with equipment
installed.
NOTE:
Please see the QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html
(Worldwide)
NOTE:
For additional information regarding Rack Cabinets and Telco Rack
support, please see the following URL:
http://www.hp.com/go/rackandpower
.
NOTE:
The increasing power of new high-performance processor technology
requires increased cooling efficiency for rack-mounted servers. The 10000 G2
Series Racks provide enhanced airflow for maximum cooling, allowing these
racks to be fully loaded with servers using the latest processors.
CAUTION:
If a third-party rack is used, observe the following additional
requirements to ensure adequate airflow and to prevent damage to the
equipment: Front and rear doors: If your 42U server rack includes closing front
and rear doors, you must allow 830 square inches (5,350 sq cm) of hole evenly
distributed from top to bottom to permit adequate airflow (equivalent to the
required 64 percent open area for ventilation). Side: The clearance between the
installed rack component and the side panels of the rack must be a minimum of
2.75 inches (7 cm).
QuickSpecs
HP ProLiant DL360 Generation 7
Additional Options
DA - 13598 Worldwide QuickSpecs — Version 29 — 4/5/2011