Reference Guide

System Flags C-7
System Flags (continued)
Flag Description
94
Auto-saving.
Clear: In RPN mode, results are stored in LASTCMD.
Set: In RPN mode, results are not stored in LASTCMD.
95
Entry Mode.
Clear: RPN mode
Set (default): Algebraic mode.
96
Not used. (Originally intended to toggle the softmenu in the editor in the HP 49G,
though it was never implemented.)
97
Vertical Lists.
Clear: Lists on stack are displayed horizontally only, like the HP 48GX.
Set: Lists are displayed vertically.
98
Vertical Vectors.
Clear: Vectors on stack are displayed horizontally only, like the HP 48GX.
Set: Vectors are displayed vertically.
99
Verbose CAS Mode.
Clear: CAS concise mode.
Set: CAS verbose mode.
100
Step-by-step CAS Mode.
Clear: Step-by-step mode.
Set: Final result mode.
101
Internal use only. (Set if VXXL success).
102
GCD Computations.
Clear: GCD computations allowed.
Set: No GCD computations.
103
Real/Complex Mode.
Clear: Real mode. “R” annunciator in header.
Set: Complex mode. “C” annunciator in header.
104
Internal use only. (If set, LN –INV[–LN]]).
105
Exact/Approximate Mode.
Clear: Exact mode. “=” annunciator in header.
Set: Approximate mode, like the HP 48GX calculator. “~” annunciator in header.
106
TSIMP Calls.
Clear: TSIMP calls are allowed in SERIES.
Set: TSIMP calls are not allowed in SERIES.
107
Internal use only. (Modular computation).
108
Internal use only. (Testing remainder to be zero).
109
Numeric/Symbolic Factorization.
Clear: Numeric factorization is not allowed.
Set: Numeric factorization is allowed.
110
Large Matrices.
Clear: Use normal-size-matrix code, like the HP 48GX calculator.
Set: Use code optimized for large matrices.
111
Simplifying Inside Non-rational Expressions.
Clear: Recursive simplification in EXPAND and TSIMP.
Set: No recursive simplification in EXPAND and TSIMP.