Reference Guide
System Flags C-3
System Flags (continued)
Flag Description
–
36
I/O Receive Overwrite.
Clear: If file name received by the calculator matches existing variable name, new
variable name with number extension is created to prevent overwrite.
Set: If file name received by the calculator matches existing variable name,
existing variable is overwritten.
–
37
Double-Spaced Printing.
Clear: Single-spaced printing.
Set: Double-spaced printing.
–
38
Line Feed.
Clear: Linefeed added at end of each print line.
Set: No linefeed added at end of each print line.
–
39
I/O Messages.
Clear: I/O messages displayed.
Set: I/O messages suppressed.
–
40
Clock Display.
Clear: Clock is not displayed.
Set: Ticking clock displayed at all times, provided the header height is 2.
–
41
Clock Format.
Clear: 12-hour clock.
Set: 24-hour clock.
–
42
Date Format.
Clear: Month/Day format.
Set: Day/Month format.
–
43
Repeat Alarm Not Rescheduled.
Clear: Unacknowledged repeat appointment alarms automatically rescheduled.
Set: Unacknowledged repeat appointment alarms not rescheduled.
–
44
Acknowledged Alarms Saved.
Clear: Acknowledged appointment alarms deleted from alarm list.
Set: Acknowledged appointment alarms saved in alarm list.
–
45
through
–
48
Number of Decimal Digits.
Combined states of flags
–
45 through
–
48 sets the number of decimal digits in
Fix, Scientific, and Engineering modes.
–
49
thru
–
50
Number Display Format.
Standard:
–
49 clear,
–
50 clear.
Fix:
–
49 set,
–
50 clear.
Scientific:
–
49 clear,
–
50 set.
Engineering:
–
49 set,
–
50 set.
–
51
Fraction Mark.
Clear: Fraction mark is . (period).
Set: Fraction mark is , (comma).
–
52
Single-Line Display.
Clear: Display gives preference to object in level 1, using multiple lines of stack
display.
Set: Display of object in level 1 restricted to one line.