Command Reference Guide

3Com Router 5000 Family and Router 6000 Family t1 set clock 317
Command Reference
t1 set clock
Purpose Use the t1 set clock command to set the clock mode for a T1 line on the CT3
interface.
Use the undo e1 clock command to restore the default or line clock.
Syntax t1 line-number set clock { master | slave }
undo t1 line-number set clock
Parameters line-number
T1 line number. Valid values are 1 to 28.
master
Internal clock.
slave
Line clock.
Example Configure the first T1 line on the T3 interface to adopt line clock.
[3Com -T3 1/0/0] t1 1 set clock slave
View This command can be used in the following views:
CT3 Interface view
Description When the CE3 interface is working in channelized mode, its E1 lines may use separate
clocks.