Command Reference Guide
3Com Router 5000 Family and Router 6000 Family t1 bert ● 313
Command Reference
Description ITU O.151, ITU O.153, and ANSI T1.403-1999 define many BERT patterns, among
which, t1 lines on the CT3 interface support only 2^11, 2^15, 2^20, 2^23, and QRSS
at present.
When running a BERT test, the local end sends out a pattern, which is to be looped
over somewhere on the line and back to the local end. The local end then checks the
received pattern for the bit error rate, and by so doing helps you determine whether
the condition of the line is good. To this end, you must configure loopback to allow
the transmitted pattern to loop back from somewhere on the line, for example, from
the far-end interface by placing the interface in far-end loopback.
You may view the state and result of the BERT test with the display controller
t3
command.