Command Reference Guide

3Com Router 5000 Family and Router 6000 Family bims specify-time 33
Command Reference
bims specify-time
Purpose Use the bims specify-time command to configure the BIMS device to access the
BIMS center at the specified time and if desired, configure the device to access the
BIMS center at regular intervals from then on during a specified period.
Use the undo bims specify-time command to delete the setting.
Syntax bims specify-time hh:mm yyyy/mm/dd [ [ hh:mm yyyy/mm/dd ] period
numberdays ]
undo bims specify-time
Parameters hh:mm yyyy/mm/dd
The first and second hh:mm yyyy/mm/dd arguments
respectively specify the start time and end time for
accessing the BIMS center. If only the first argument is
specified, the BIMS device accesses the BIMS center at
that time once.
numberdays
Period in days for accessing the BIMS center.
Example Configure the router to access the BIMS center at 01:01 on December 12, 2004, and
from then on, to access the BIMS center at seven-day intervals until December 12,
2005 01:01. If the current time has not reached the specified start time, after the
above configuration, the router will access the BIMS center at 01:01 on December 12,
2004 and at 01:01 on December 19, 2004 after a 7*24 hours interval for the next
time.
[3Com] bims specify-time 01:01 2004/12/12 01:01 2005/12/12 period 7
View This command can be used in the following views:
System view
Description The precision of the timer is one minute. The device will access BIMS center in one
minute after the specified time.